VOC Gas
Sensor Head Specifications
Measurement range |
0 to 400 ppm toluene |
Accuracy |
< +/- 10 ppm (0 – 200 ppm)
< +/- 10% ( > 200
ppm) |
T90 response |
< 60 s |
Sensor type |
Gas-sensitive semiconductor |
Operating temperature range |
-20°C to 60°C |
Operating relative humidity
range |
5 to 95% non-condensating |
VOC Gas
Monitoring Products
VOC gas sensor heads are compatible with all Aeroqual monitoring products.
The sensor heads measure the VOC content of ambient air and
utilize the proprietary Aeroqual "Gas Sensitive Semiconductor" (GSS)
technology.
All Aeroqual products have removable sensor heads that eliminate
the need for field calibration and facilitate sensor head replacement
as required.
Select one of the Product Categories from the links on the right
to access the appropriate product selection chart.
Specific Calibrations to other VOC gases are available on request.