IQM 60 Indoor Air Quality MonitorIQM 60 Indoor Air Quality Monitor

The complete instrument for analysis of indoor air quality

The IQM 60 Indoor Air Quality Monitor enables simultaneous monitoring of common indoor air quality parameters with a single instrument.

IQM 60 Indoor Air Quality MonitorAeroqual's proprietary Analytic GSS Technology is integrated with photo-ionization detector (PID) and nondispersive infra-red (NDIR) sensors to achieve cost effective and precise measurement of gases including carbon dioxide (CO2), carbon monoxide (CO), volatile organic compounds (VOC), nitrogen dioxide (NO2) and ozone (O3). Other sensors are integrated for measuring temperature, humidity and particulate matter.

Air quality data for each parameter is logged to a removable SD card or to a PC in real-time and can be exported for generating reports. Applications include IAQ and HVAC analysis, IAQ complaint investigation, and Sick Building Syndrome (SBS) assessment. The IQM 60 offers the complete package for performing in-depth analysis of indoor air quality.

 

Features

  • Multiple Gas Measurements
  • Temperature and Relative Humidity
  • GSS, PID and NDIR Sensor Technology
  • Factory Certified - NIST Traceable
  • Temperature and Humidity Sensors
  • Particulate Measurement Options
    - Particle Counter: 2-channel
    - Particulate Profiler: 8-channel
    - Particle Monitor: TSP, PM1, PM2.5, PM10
  • Active-air Sampling System
  • Multi-point Factory Sensor Calibration
  • Zero and Span Calibration User-facility
  • Real-time Data Sampling
  • Removable Data Storage
  • PC Data-logging Software
  • Wireless Communication Options
  • Compact and Portable
  • Low Maintenance

Applications

  • IAQ Complaint Investigation and Analysis
  • HVAC System Performance Monitoring
  • Sick Building Syndrome (SBS) Surveys
  • Health and Comfort Assessment
  • Odour Investigation and Remediation
  • Testing the Efficiency of Air Purifiers
  • Clean Room Monitoring and Verification
  • Filtration Testing
  • Residential and Commercial Buildings
  • Airport Lounges and Shopping Malls
  • Schools and Kindergartens
  • Hospitals and Elderly Care Facilities
  • Epidemiological Studies
  • Re-entrainment Studies

top

Specifications

Environment Operating Range
Non-condensing
Temperature 0°C to 50°C
Humidity 5 to 95% RH
Instrument Display
Shows parameter, value and unit in real-time
VFD 4-line x 20-character
Scrolling data display
Communication Interface RS 232 com port
Cable and USB adaptor supplied
Remote Communication (optional) GSM/GPRS modem | Ethernet
Wireless communication
Power Supply (standard) Desktop switching power supply 12VDC
Input 90-260VAC | 47-63Hz
Portable Power Station (optional)

Li-ion battery station and charger
222WH or other capacity

Enclosure (standard models) 278 x 236 x 132 (mm)
Aluminium and powder-coated steel
Enclosure (particle monitor models) 378 x 236 x 132 (mm)
Aluminium and powder-coated steel
Instrument Weight Net 4-9 Kg
(subject to configuration)
Instrument Carry Case
Supplied standard
Aluminium and powder coated steel
278L x 236W x 132H (mm)
Maintenance Checks Routine> 3 months | 6 months | 12 months
(subject to application)
Safety and Compliance Approvals Power Supply: Safety; EMC Conformity
UL | CUL | TUV | BSMI | CCC
CB | FCC | CE UL60950-1,
TUV EN60950-1, BSMI CNS14336, CCCGB4943;
EN55022 class B, FCC PART 15, CISPR22 class B, CNS13438 class B, GB9254 class B;
EN61000-3-2,3, GB17625.1;
EN61000-4-2,3,4,5,6,8,11


Gas Modules: EMC Conformity
Part 15 FCC Rules; EMC 2004/108/EC;
EN 61000-6-1: 2001, EN 61000-6-3: 2001


Particle Monitor and Particulate Profiler
Class 1 laser;
IEC 60825-1:1998 Directive 72/23/EEC;
EN 61010-1; EN 60825-1:1996);
US 21 CFR 1040.10

top

 

Gas Modules

Gas Modules
Base configuration has CO2 and CO (fit up to 6 modules)
Calibrated Sensor Range

Minimum Detection Limit

Accuracy of
Factory Calibration

Precision

Resolution

Carbon dioxide CO2
(NDIR) IQMCD
0-2000 ppm 6 ppm
<40 ppm + 3% of reading 10 ppm 1 ppm
Carbon dioxide CO2
(NDIR) IQMCD
0-5000 ppm 6 ppm <150 ppm + 5% of reading 10 ppm
1 ppm
Carbon monoxide CO
(GSS) IQMCN
0-100 ppm 0.2 ppm <±2 ppm 0-20 ppm;
<±10% 20-100 ppm
0.2 ppm 0.1 ppm
Ozone O3
(GSS) IQMUZ
0-0.15 ppm 0.001 ppm <±0.005 ppm 0.002 ppm 0.001 ppm
Ozone O3
(GSS) IQMLZ
0-0.5 ppm 0.001 ppm <±0.008 0-0.1 ppm;
<±10% 0.1-0.5 ppm
0.005 ppm 0.001 ppm
Volatile organic compounds
(PID) IQMPD
0-20 ppm 0.01 ppm <±10% 0.02 ppm 0.01 ppm
Volatile organic compounds
(GSS) IQMVM
0-25 ppm 0.1 ppm <±10% 0.2 ppm 0.1 ppm
Nitrogen dioxide
NO2 (GSS) IQMNW
0-0.2 ppm 0.001 ppm <±0.010 0-0.1 ppm;
<±10% 0.1-0.2 ppm
0.005 ppm 0.001 ppm
Non-methane hydrocarbon
(GSS) IQMVN
0-25 ppm 0.1 ppm <±10% 0.2 ppm 0.1 ppm

NB: Gas concentration displays in ppm on the instrument and is available in ppm or mg/m3 via the supplied PC software

top

Temperature and Humidity Probe


Temperature Range Humidity Range Accuracy T | RH @ 25°C T Resolution RH Resolution
CMOS technology -20°C to +100°C 0-100% RH ±0.3°C | ±2% RH 0.01°C 0.1% RH

Particulate Profiler: 2-channel option


Range Sensitivity Accuracy Precision Resolution
Sizes and counts particles into two digital bins 0-100000 Particles/L >0.3 μm | >2.5 μm ±10% to calibration aerosol 0.3 μm Particles/L

top

Particulate Profiler: 8-channel option

 

Range Sensitivity Accuracy Precision Resolution
Sizes and counts particles into eight digital bins 0-100000 Particles/L 0.3-10 μm (8) ±10% to calibration aerosol 0.3 μm Particles/L

top

Particle Monitor: TSP option


Range Cut Sizes Accuracy Precision Resolution
Optional interchangeable sharp cut cyclones 0-2000 μg/m³ PM1 | PM2.5 | PM10 8% of NIOSH 0600 3 μg/m³ 1 μg/m³

top

Controller and Data Storage


Communication Data Storage Data Sampling Rate Diagnostics PC Software
Single-board computer (SBC) RS 232 (real-time) 2 GB SD card 2-255 min. (programmable) Remote access Included

top

Sampling System


Zero Air Scrubber Sampling Pump Zero and Span Calibration Scrubber Inlet Filter
Sampling and
distribution system
Internal or External Diaphragm Facilitate with standard cal gases Replaceable Replaceable

top