IQM 60 Indoor Air Quality Monitor
The complete instrument for analysis of indoor air quality
The IQM 60 Indoor Air Quality Monitor enables simultaneous monitoring of common indoor air quality parameters with a single instrument.
Aeroqual's proprietary Analytic GSS Technology is integrated with photo-ionization detector (PID) and nondispersive infra-red (NDIR) sensors to achieve cost effective and precise measurement of gases including carbon dioxide (CO2), carbon monoxide (CO), volatile organic compounds (VOC), nitrogen dioxide (NO2) and ozone (O3). Other sensors are integrated for measuring temperature, humidity and particulate matter.
Air quality data for each parameter is logged to a removable SD card or to a PC in real-time and can be exported for generating reports. Applications include IAQ and HVAC analysis, IAQ complaint investigation, and Sick Building Syndrome (SBS) assessment. The IQM 60 offers the complete package for performing in-depth analysis of indoor air quality.
Features
- Multiple Gas Measurements
- Temperature and Relative Humidity
- GSS, PID and NDIR Sensor Technology
- Factory Certified - NIST Traceable
- Temperature and Humidity Sensors
- Particulate Measurement Options
- Particle Counter: 2-channel
- Particulate Profiler: 8-channel
- Particle Monitor: TSP, PM1, PM2.5, PM10
- Active-air Sampling System
- Multi-point Factory Sensor Calibration
- Zero and Span Calibration User-facility
- Real-time Data Sampling
- Removable Data Storage
- PC Data-logging Software
- Wireless Communication Options
- Compact and Portable
- Low Maintenance
|
Applications
- IAQ Complaint Investigation and Analysis
- HVAC System Performance Monitoring
- Sick Building Syndrome (SBS) Surveys
- Health and Comfort Assessment
- Odour Investigation and Remediation
- Testing the Efficiency of Air Purifiers
- Clean Room Monitoring and Verification
- Filtration Testing
- Residential and Commercial Buildings
- Airport Lounges and Shopping Malls
- Schools and Kindergartens
- Hospitals and Elderly Care Facilities
- Epidemiological Studies
- Re-entrainment Studies
|
top
Specifications
Environment Operating Range Non-condensing |
Temperature 0°C to 50°C Humidity 5 to 95% RH |
Instrument Display Shows parameter, value and unit in real-time |
VFD 4-line x 20-character Scrolling data display |
| Communication Interface |
RS 232 com port Cable and USB adaptor supplied |
| Remote Communication (optional) |
GSM/GPRS modem | Ethernet Wireless communication |
| Power Supply (standard) |
Desktop switching power supply 12VDC Input 90-260VAC | 47-63Hz |
| Portable Power Station (optional) |
Li-ion battery station and charger 222WH or other capacity |
| Enclosure (standard models) |
278 x 236 x 132 (mm) Aluminium and powder-coated steel |
| Enclosure (particle monitor models) |
378 x 236 x 132 (mm) Aluminium and powder-coated steel |
| Instrument Weight |
Net 4-9 Kg (subject to configuration) |
Instrument Carry Case Supplied standard |
Aluminium and powder coated steel 278L x 236W x 132H (mm) |
| Maintenance Checks Routine> |
3 months | 6 months | 12 months (subject to application) |
| Safety and Compliance Approvals |
Power Supply: Safety; EMC Conformity
UL | CUL | TUV | BSMI | CCC CB | FCC | CE UL60950-1,
TUV EN60950-1, BSMI CNS14336, CCCGB4943;
EN55022 class B, FCC PART 15, CISPR22 class B,
CNS13438 class B, GB9254 class B; EN61000-3-2,3,
GB17625.1; EN61000-4-2,3,4,5,6,8,11
Gas Modules: EMC Conformity
Part 15 FCC Rules; EMC 2004/108/EC;
EN 61000-6-1: 2001, EN 61000-6-3: 2001
Particle Monitor and Particulate Profiler
Class 1 laser; IEC 60825-1:1998 Directive 72/23/EEC; EN
61010-1; EN 60825-1:1996); US 21 CFR 1040.10 |
top
|