Home

 

Series 130
Controller

 

Specifications

Base Unit

Power (user supplied)

24 VDC, (range 16 – 28 VDC), 500 mA

I/O connectors (power, control signal)

Eight pole M12 female panel mount connector and eight pole male cord connector

Setting control and alarms

dip switches

External signal for control & switching

Volt free (150 mA max, 24VDC max, resistive)

External signals

2

External signal functions

Alarm (Low Alarm & High Alarm) or Control

Removable / replaceable sensor head

Yes

LED status indicator

Low, high, within control band, diagnostics

Enclosure rating

IP41 & NEMA 2 equivalent

Enclosure size

180W x 110H x 90D (mm); 7?W x 4¾H x 3½D (in)

Enclosure casing

Fibre reinforced plastic

Weight

< 850 g; < 30 oz

Approvals

Part 15 of the FCC Rules
EN 55022: 1998
EN 61000-6-1: 2001

 

 


Monitor Specifications Sheet

For further information regarding this product please download the product brochure.

Download Specifications
PDF 99k


User Guide

Download User Guide
PDF 99k

Ozone Sensor Head Specifications

Sensor Heads

Low

High

Leak

Measurement range

0.000 - 0.500 ppm

0.50 - 20.00 ppm

0.00 - 50.00 ppm

Accuracy

< 0.008 ppm (0 - 0.100 ppm)

± 10% (0.100 – 0.500 ppm)

± 10% (0.20 - 2.00 ppm)

± 15% (2.00 - 20.00 ppm)

± 20%,

15 seconds after Reset

Resolution

0.001 ppm

0.01 ppm

0.01 ppm

Controlled Atmosphere Version

Available on Request

Available on Request

Available on Request

T90 Response

< 60 seconds (T90)

< 35 seconds (T90)

< 10 seconds

Sensor type

Gas-sensitive semiconductor

Operating temperature range

-5°C to 50°C; 23°F to 122°F (sensor head and base unit)

Relative humidity limit

95% maximum (sensor head and base unit)

VOC Sensor Head Specification*

Measurement range

0 to 400 ppm toluene

Accuracy

< +/- 10 ppm (0 – 200 ppm)

< +/- 10% ( > 200 ppm)

T90 response

< 60 s

Sensor type

Gas-sensitive semiconductor

Operating temperature range

-20°C to 60°C

Operating relative humidity range

5 to 95% non-condensating

* Specific Calibrations to other VOC's available – contact Aeroqual Sales

Ammonia Sensor Head Specification

Measurement range

0 to 1000 ppm

Accuracy

< +/- 5 ppm (0 – 100 ppm) < +/- 10% (100 – 1000 ppm)

T90 response

< 60 s

Sensor type

Gas-sensitive semiconductor

Operating temperature range

-20°C to 60°C;

Operating relative humidity range

5 to 95% non-condensating

CO Sensor Head Specification

Measurement range

0 to 2000 ppm carbon monoxide

Accuracy

< +/- 10 ppm in the range 0 to 400 ppm

T90 response

< 150s

Sensor type

Gas-sensitive semiconductor

Operating temperature range

0°C to 70°C;

Operating relative humidity range

5 to 95% non-condensating

Approvals

UL 2034, BS 7860