Home

 

Series 200
Monitor

 

Monitor Specifications

Series 200 Monitor Base

Measurement units

ppm

Removable / replaceable sensor head

Yes

On-board alarm

No

Alarm status displayed

No

Low battery indication

Yes

Alarm mute function

No

Sensor condition status

Yes

Stand-by mode

Yes

External signal for alarms & control

None

External signal functions

None

Analogue output

None

Power supply

12 VDC, 800 mA

Rechargeable battery pack (2 x options)

 

Standard 9.6V ( 940mA/hr Ni-Cd)

Long Life

9.6V (2100mA/hr Ni-MH)

Portable

Yes

Permanently fixable

Screw fix

Remote Sensor Capability

Yes

Enclosure rating

IP20 & NEMA 1 equivalent

Size (with sensor head)

195 x 122 x 54 (mm); 7? x 4¾ x 2? (in)

Weight (with sensor head and battery)

< 460 g; < 16 oz

Approvals

Part 15 of FCC Rules
EN 50082-1: 1997
EN50081-1: 1992

 

 

Monitor Specifications Sheet

For further information regarding this product please download the product brochure.

Download Specifications
PDF 99k


User Guide

Download User Guide
PDF 99k

Ozone Sensor Head Specifications

Sensor Heads

Low

High

Leak

Measurement range

0.000 - 0.500 ppm

0.50 - 20.00 ppm

0.00 - 50.00 ppm

Accuracy

< 0.008 ppm (0 - 0.100 ppm)

± 10% (0.100 – 0.500 ppm)

± 10% (0.20 - 2.00 ppm)

± 15% (2.00 - 20.00 ppm)

± 20%,

15 seconds after Reset

Resolution

0.001 ppm

0.01 ppm

0.01 ppm

Controlled Atmosphere Version

Available on Request

Available on Request

Available on Request

T90 Response

< 60 seconds (T90)

< 35 seconds (T90)

< 10 seconds

Sensor type

Gas-sensitive semiconductor

Operating temperature range

-5°C to 50°C; 23°F to 122°F (sensor head and base unit)

Relative humidity limit

95% maximum (sensor head and base unit)

VOC Sensor Head Specification*

Measurement range

0 to 400 ppm toluene

Accuracy

< +/- 10 ppm (0 – 200 ppm)

< +/- 10% ( > 200 ppm)

T90 response

< 60 s

Sensor type

Gas-sensitive semiconductor

Operating temperature range

-20°C to 60°C

Operating relative humidity range

5 to 95% non-condensating

* Specific Calibrations to other VOC's available – contact Aeroqual Sales

Ammonia Sensor Head Specification

Measurement range

0 to 1000 ppm

Accuracy

< +/- 5 ppm (0 – 100 ppm) < +/- 10% (100 – 1000 ppm)

T90 response

< 60 s

Sensor type

Gas-sensitive semiconductor

Operating temperature range

-20°C to 60°C;

Operating relative humidity range

5 to 95% non-condensating

CO Sensor Head Specification

Measurement range

0 to 2000 ppm carbon monoxide

Accuracy

< +/- 10 ppm in the range 0 to 400 ppm

T90 response

< 150s

Sensor type

Gas-sensitive semiconductor

Operating temperature range

0°C to 70°C;

Operating relative humidity range

5 to 95% non-condensating

Approvals

UL 2034, BS 7860