Ozone Sensor Head Specifications
Sensor Heads |
Low |
High |
Leak |
Measurement range |
0.000 - 0.500 ppm |
0.50 - 20.00 ppm |
0.00 - 50.00 ppm |
Accuracy |
< 0.008 ppm (0 - 0.100 ppm)
± 10% (0.100 – 0.500 ppm) |
± 10% (0.20 - 2.00 ppm)
± 15% (2.00 - 20.00 ppm) |
± 20%,
15 seconds after Reset |
Resolution |
0.001 ppm |
0.01 ppm |
0.01 ppm |
Controlled Atmosphere Version |
Available on Request |
Available on Request |
Available on Request |
T90 Response |
< 60 seconds (T90) |
< 35 seconds (T90) |
< 10 seconds |
Sensor type |
Gas-sensitive semiconductor |
Operating temperature range |
-5°C to 50°C;
23°F to 122°F (sensor head and base unit) |
Relative humidity limit |
95% maximum (sensor
head and base unit) |
VOC Sensor Head Specification*
Measurement range |
0 to 400 ppm toluene |
Accuracy |
< +/- 10 ppm (0 – 200 ppm)
< +/- 10% ( > 200 ppm) |
T90 response |
< 60 s |
Sensor type |
Gas-sensitive semiconductor |
Operating temperature range |
-20°C to 60°C |
Operating relative humidity range |
5 to 95% non-condensating |
* Specific Calibrations to other VOC's available – contact Aeroqual
Sales
Ammonia Sensor Head Specification
Measurement range |
0 to 1000 ppm |
Accuracy |
< +/- 5 ppm (0 – 100 ppm) < +/-
10% (100 – 1000 ppm) |
T90 response |
< 60 s |
Sensor type |
Gas-sensitive semiconductor |
Operating temperature range |
-20°C to 60°C; |
Operating relative humidity range |
5 to 95% non-condensating |
CO Sensor Head Specification
Measurement range |
0 to 2000 ppm carbon monoxide |
Accuracy |
< +/- 10 ppm in the range
0 to 400 ppm |
T90 response |
< 150s |
Sensor type |
Gas-sensitive semiconductor |
Operating temperature range |
0°C to 70°C; |
Operating relative humidity range |
5 to 95% non-condensating |
Approvals |
UL 2034, BS 7860 |
|