Home

 

Series 935 Transmitter/Controller
With Temperature Sensor

 

Specifications

Base Unit

Power (user supplied)

24VDC, 500mA (range 22-26 VDC)

Analogue output

4-20 mA (opto-isolated), 12-24 V

External signal type

Transistor Output

External signals

4

External signal functions

LED Display

Low Alarm, High Alarm, Control & Diagnostics

(Optional)

Inputs

Standby toggle

Communication

RS485

Jumpers

J1, J2, J3 termination resistors

Connectors

Screw

ID

1 (Default)
User configurable from 1 - 255

Alarm set points (2)

User configurable

Control set point

User configurable

RS485 protocol

Aeroqual proprietary product

Removable / replaceable sensor head

Yes

Enclosure rating

IP41 & NEMA 2 equivalent

Enclosure size

180W x 110H x 90D (mm); 7?W x 4¾H x 3½D (in)

Enclosure casing

Fibre reinforced polycarbonate

Weight

< 850 g; < 30 oz

Approvals

Part 15 of the FCC Rules
EN 50082-1: 1997
EN 50081-1: 1992

Temperature and Humidity Sensors

Accuracy

Resolution

Range

Temperature

± 0.3 [K] @ 25°C

0.04 min resolution

range -40°C to 124°C

Humidity

±1.8% RH

0.4 min resolution

range 0 100%

 

 


Monitor Specifications Sheet

For further information regarding this product please download the product brochure.

Download Specifications
PDF 99k


User Guide

Download User Guide
PDF 953k

Ozone Sensor Head Specifications

Sensor Heads

Low

High

Leak

Measurement range

0.000 - 0.500 ppm

0.50 - 20.00 ppm

0.00 - 50.00 ppm

Accuracy

< 0.008 ppm (0 - 0.100 ppm)

± 10% (0.100 0.500 ppm)

± 10% (0.20 - 2.00 ppm)

± 15% (2.00 - 20.00 ppm)

± 20%,

15 seconds after Reset

Resolution

0.001 ppm

0.01 ppm

0.01 ppm

Controlled Atmosphere Version

Available on Request

Available on Request

Available on Request

T90 Response

< 60 seconds (T90)

< 35 seconds (T90)

< 10 seconds

Sensor type

Gas-sensitive semiconductor

Operating temperature range

-5°C to 50°C; 23°F to 122°F (sensor head and base unit)

Relative humidity limit

95% maximum (sensor head and base unit)

VOC Sensor Head Specification*

Measurement range

0 to 400 ppm toluene

Accuracy

< +/- 10 ppm (0 200 ppm)

< +/- 10% ( > 200 ppm)

T90 response

< 60 s

Sensor type

Gas-sensitive semiconductor

Operating temperature range

-20°C to 60°C

Operating relative humidity range

5 to 95% non-condensating

* Specific Calibrations to other VOC's available contact Aeroqual Sales

Ammonia Sensor Head Specification

Measurement range

0 to 1000 ppm

Accuracy

< +/- 5 ppm (0 100 ppm) < +/- 10% (100 1000 ppm)

T90 response

< 60 s

Sensor type

Gas-sensitive semiconductor

Operating temperature range

-20°C to 60°C;

Operating relative humidity range

5 to 95% non-condensating

CO Sensor Head Specification

Measurement range

0 to 2000 ppm carbon monoxide

Accuracy

< +/- 10 ppm in the range 0 to 400 ppm

T90 response

< 150s

Sensor type

Gas-sensitive semiconductor

Operating temperature range

0°C to 70°C;

Operating relative humidity range

5 to 95% non-condensating

Approvals

UL 2034, BS 7860