The Aeroqual School Air Quality Testing Kit can be used by teachers to educate students on measuring the common pollutants found near schools. Features Aeroqual’s proven Series 500 portable monitor with interchangeable sensor heads, measuring particulate matter (PM2.5, PM10), temperature and relative humidity, and either nitrogen dioxide (NO2) or ozone (O3). Suitable for use as an educational learning tool and for raising pollution awareness within the school community.

Includes swappable sensor heads, measuring particulate matter (PM2.5, PM10), and either nitrogen dioxide (NO2) OR ozone (O3)

Gather data in real-time using the Series 500’s inbuilt real-time data logger

Long-life lithium battery and in-field calibration make this an easy-to-use kit, delivering highly accurate results

Product overview

The School Air Quality Testing Kit features industry-quality instruments used by researchers and air quality professionals around the world in an affordable, easy-to-use package. Simply swap out the sensor head on the Series 500 portable monitor for the pollutant you wish to monitor. Nitrogen dioxide (NO2) and particulate matter (PM) are emitted directly by stationary vehicles, and ozone (O3) is created when NO2 and volatile organic compounds (VOCs) combine in the presence of sunlight. The health risks of overexposure to these pollutants are well-documented. This kit also includes a combined temperature and relative humidity sensor.

Protect your school and your community, learning more about the quality of your outdoor air, keeping parent in the know, and lobbying local authorities for pollution reduction measures. For a full set of tools, including additional sensor heads measuring CO and VOCs, see the Outdoor Air Quality Test Kit (Pro).

What can it measure?

The School Air Quality Testing Kit combines the Aeroqual Series 500 portable monitor with the following interchangeable sensors:

  • Particulate Matter Sensor (PM10, PM2.5)

  • Either an Ozone Sensor 0-0.15ppm OR a Nitrogen Dioxide Sensor 0-1ppm

  • Temperature & Humidity Sensor

The Series 500 monitor also comes with:

  • LCD digital display

  • Lithium battery and charger

  • In-built datalogger

  • Monitor to USB cable

  • PC software

  • Small carry case

Key benefits of Aeroqual products

Key benefits of Aeroqual products
Industry-leading sensor technology

As sensor manufacturers, we know sensors inside and out and have unparalleled expertise in optimizing performance in real-world conditions.

Protect health and safety of workers with real time industrial hygiene air monitoring
Powerful software platform

Leveraging deep integration with our monitoring systems, we deliver software functionality unmatched by off the shelf data acquisition systems.

Key benefits of Aeroqual products
Value-adding services

Using proprietary system diagnostics, we enable proactive maintenance with hassle-free services that virtually eliminate system downtime.

Who is it for?

Teachers and school administrators use the School Air Quality Testing Kit to educate students about air pollution, raise awareness of air pollution within the local community, and lobby for positive change. 

Practical applications for the School Air Quality Testing Kit include: 

  • Educational learning tool

  • Raising pollution awareness within the school community

  • Understanding air quality in and around schools

  • Personal exposure monitoring

Working with your sector

air-quality-monitoring-on-remediation-sites

Construction

Reduce risk and enhance your reputation by investing in a real-time construction site dust monitoring system.

Read more
Construction-Site-Dust-Monitoring

Remediation

Exceed environmental and human health standards by investing in a premium all-in-one air monitoring system.

Read more
Aeroqual Ranger Portable Air Monitor

Industrial Hygiene

Maximize the health and productivity of your workforce with a real-time industrial hygiene air monitoring system from Aeroqual.

Read more
Indoor air quality monitoring solutions from Aeroqual

Indoor Air Quality

Achieve a healthier, safer and more productive workplace by investing in an indoor air quality testing system.

Read more

Related products

OUR CUSTOMERS
  • Aeroqual
  • Aeroqual
  • Aeroqual
  • Aeroqual
  • Aeroqual
  • Aeroqual
  • Aeroqual
  • Aeroqual
  • Aeroqual
  • Aeroqual

Optional accessories

S500 PC software download

Download the S500 Series PC software here.

FAQs

There are many different types of outdoor air pollution. Measuring them all would be too expensive, so regulators focus on a smaller group of common air pollutants, sometimes known as the criteria pollutants. The criteria pollutants are:

  • Nitrogen dioxide (NO2)

  • Sulfur dioxide (SO2)

  • Carbon monoxide (CO)

  • Ozone (O3)

  • Particulate matter (PM)

As always requirements should be confirmed with your local regulatory body.

Sensors are housed within an interchangeable ‘sensor head’ that attaches to the monitor base. You can choose from up to 28 different gas and particulate sensor heads. Each sensor head contains a single gas or particle sensor. Swapping sensor heads takes seconds and no configuration or re-calibration is required.

You can find our specifications for our sensor heads here:

Aeroqual-Portable-Fixed-Sensor-Specifications.pdf

Note: Accuracy may drift as the sensor ages.

Aeroqual recommends replacement after two years, however higher exposure levels or harsh environments can lead to a significant reduction in life expectancy. Your monitor display is likely to indicate Sensor Failure or Sensor Ageing if the sensor is nearing the end of its useful life.

Note: Sensor heads may degrade even when unused and in storage.

How many sensors can I use on the monitor at once?

You can only connect one gas or particulate sensor head at a time to monitor. However, you are able to connect the optional temperature and humidity sensor at the same time as a gas or particulate sensor head.

Can I use the PM sensor head with any portable monitor?

The PM sensor is compatible with Series 200/300/500 monitors with software version 6.4 introduced in November 2014.

What is the PPM to mg/m³ conversion factor?

PPM is an absolute measurement, whilst mg/m3 varies depending upon pressure and temperature. The portable monitor measures in PPM and applies a conversion factor if you wish to measure in mg/m3.

NH3 - 0.76, CO - 1.25, CO2 - 1.96, CL2 - 3.16, CH2O - 1.34, H2 - 0.082, CH4 - 0.72, H2S - 1.52, NO2 - 2.05, NMHC - 2.5, O3 - 2.14, C2CL4 - 6.78, SO2 - 2.86, VOC - 2.5, PM - N/A*

*as particulate matter varies in size, unlike a gas molecule, PPM is not a valid unit of measurement

Do I return the instrument for calibration?

Only the sensor head needs to be calibrated. The base unit does not need to be calibrated. All parameters are stored on the sensor head.

The sensor head calibration should be completed after the first year. Aeroqual does not recommend a second factory calibration, but rather replacement after two years of operation.

See a range of frequently asked questions on calibration here.

How long can I log data for (Series 500 only)?

The Series 500 handheld unit can store a limited number of data points (8188), meaning that the length of time that data can be logged depends upon the frequency and number of data points recorded. For example:

  • If you are logging every minute for one gas (i.e. one data point per minute) you can log for 8188 minutes.

  • If you are logging every minute for one gas, temperature and humidity (i.e. 3 data points per minute) you can log for 2729 minutes.

Decrease the logging frequency for the ability to log over a longer timeframe.

Note: Once capacity is reached new data will begin to overwrite the oldest logged data.

What communication options does the portable monitor have?

S200: None

S300: 0-5V Analog output (current reading only)

S500: 0-5V Analog output (current reading only), RS232 (current, logged data and instrument control) to PC software via USB adapter. RS232 protocol available upon request for third party software integration.

What is the “Control” function (Series 300 & 500 only)?

This is designed to control generation of a gas such as ozone from an ozone generator. The control pin can be wired to control a gas concentration between upper and lower concentration limits. The upper and lower limits can be set by the user via this control function.

Refer to the relevant section of the user guide for wiring instructions.

What accessories are available for the portable monitors?

Aeroqual offers a range of accessories to suit your application. See the range here.

Product Support

For support on your S Series instrument, click here to visit our support centre.

Air monitoring made easy

Take the time and hassle out of your next project with a real-time air quality monitoring solution.

Talk to us about your project