Modern Geosciences Texas Landfill - rooftop monitoring

How to conduct an air quality study of a large landfill within budget

The Customer

Modern Geosciences, based in Colleyville, TX, is a trusted environmental advisor to industrial, commercial, retail and government sectors. Through the use of innovative equipment and effective sampling designs, Modern Geosciences helps their clients understand concerns related to air quality during remediation projects, at industrial operations or production facilities, and within ambient air sheds.

The Aeroqual stations gave us defensible data for multiple pollutants within budget and were easy to deploy onsite. This approach enabled us to meet the study objectives plus mitigate environmental and financial impact for the client. The City will repeat the study in the future.

Kenneth Tramm, PhD, PG, CHMM
Download Case Study
Modern Geosciences Texas Landfill - rooftop monitoring

The Problem

Like everything in Texas, the landfills are bigger! At almost 1,000 acres this facility is one of the largest in the southern United States and accepts about 2 million tons of waste annually from the surrounding communities. Operated by a municipality intent on minimizing its carbon footprint, over 5 million cubic feet of landfill gas is collected each day amounting to an estimated $1.6 million in natural gas sales annually. With careful environmental management the facility will have capacity for another 40 years.

Air quality issues at Texas Landfill

Nearby residents had voiced concerns about air quality, specifically dust, odor and noise complaints. One mile to the west of the landfill is a Sensitive Receptor Area (SRA) consisting of residential, schools, and recreational parks. However, between the SRA and landfill is a high traffic corridor and an industrial corridor (businesses using chemicals, small landfills, gas stations and salvage yards). In addition to the landfill 34 possible industrial emission sources were identified which compounded the issue.

In response, the City proposed a comprehensive study to:

  1. Determine if there are air quality issues near the landfill and if so, collect data that could aid in determining possible sources.
  2. Identify areas where improvements at the landfill could lessen air quality impacts to the neighboring community.

The Solution

The City selected Modern Geosciences, to review the study area for possible sources and contaminants, determine optimum monitoring sites, inspect the perimeter areas around the landfill, complete the air quality evaluation, and provide findings and recommendations. The scope included continuous sampling for PM10, PM2.5, total volatile organic compounds (tVOC), ozone, hydrogen sulfide, methane and noise. Discrete sampling included over 50 target VOCs evaluated by gas chromatography–mass spectrometry (GC-MS). The study specified multiple monitoring sites plus wind speed and direction data for accurately determining source apportionment.

Texas Landfill air quality study - AQM 65 locations

In the past, continuous defensible data for this range of air pollutants required reference air quality analyzers. However, this approach is expensive for multiple sites and entails additional infrastructure for operating in tough conditions. To fulfill the project brief, Modern Geosciences purchased three AQM 65 Compact Air Quality Stations from Aeroqual’s distributor JJ Wilbur Co. The team affectionately named each AQM 65 after First Ladies, Edith, Ida and Eleanor, in a nod to the trusted role they would play in the study. The stations were installed at three monitoring sites: at a Fire Station located in the SRA, on the landfill Administrative Building close to the industrial corridor, and at an anticipated downwind facility. Measurements were also collected at seven discrete monitoring points to supplement the continuous data. Each AQM 65 collected 45,000 continuous readings for PM10, PM2.5, tVOC, H2S, ozone and methane as well as wind data during the 5-week monitoring program over the summer.

Evaluation

Collected data quality was very high. PM measurements from AQM-1 and AQM-3 located outside the landfill exhibited good correlation with the TECQ CAMS station situated 12 miles away. Exceedances of the 35 μg/m3 NAAQS criteria for PM2.5 were observed from AQM-2 located inside the landfill which were attributed to diesel engine exhaust. Consistent with the regional background, exceedances of the NAAQS for ozone (0.070 ppmv) were noted for brief periods in 8-hr TWA data from all sites. No significant impacts of tVOC (>0.100 ppmv) exhibited at the off-site discrete or continuous monitoring points. An elevated tVOC event (0.119 ppmv) was noted at AQM-1 in the SRA. Modern Geosciences used GC-MS results to field verify the source of the discreet event as oven cleaning chemicals used within the Fire Station.

Modern Geosciences Texas Landfill - instrument check

Based on the data collected in the study the landfill did not appear to impact the SRA. However, several items were noted at the landfill that could not only enhance their compliance program, but lessen the potential for future impacts to the SRA or surrounding communities. The City has asked Modern Geosciences to repeat the study in the near future after planned improvements are completed.

Related Products

  • air monitoring software
  • AQM 65 Air Monitoring Station with Integrated Calibration

  • AQM 65 Ambient Air Monitoring Station